A W14 x 53 section is encased in an 18 in x 22 in concrete section. The composite column is 15 ft in length. In addition to the steel hot-rolled section, 4 #9 bars are placed as shown across the column cross-section. Determine the design strength, ϕP n , for the composite column
↧